MENU

Party Walls

Become a Carbon Hero with Five Easy Tactics

Before you can really dig deep into the advanced design concepts of embodied carbon analysis and whole building energy modeling, you must first perform some bare minimum prep work. An easy way to get the pre-schematic plan up on its legs quickly is to add qualitative performance measures to the architect’s program study or create an Owners Project Requirements (OPR) document. For this article, “qualitative performance measures” refer to the metrics that express embodied carbon, but can also include operational energy, water, and even healthy materials.

Integrated Design Process ImageAn integrated design process (IDP) anchors the architectural program to performance metrics such as carbon dioxide equivalents (CO2e), Energy Use Intensity (EUI), and zero Energy Performance Index (zEPI). So, by completing the IDP, you’re getting the basic tools to optimize embodied carbon and operational energy use in your design:

  1. Target the early phase of the project
  2. Prepare a Carbon Hotspot and Simple Box energy analysis to compare carbon sensitivity of different schemes not limited to wall and roof construction, massing, and solar exposure.
  3. Schedule a workshop with the design team and owner to discuss findings and recommendations.
  4. Establish performance targets such as total Carbon Dioxide equivalents as a basic program requirement.
  5. Choose a compliance pathway and verify design with Life Cycle Analysis and a Whole Building Energy model.

(more…)

Climate Week NYC: Seven Days of Climate Action and Discussion

 

Climate Week logoLast week, as I was writing this blog, I came across a New York Times article: “The Amazon, Siberia, Indonesia: a World of Fire.” By now, I’m sure most of us are aware that the Amazon Rainforest has been burning for weeks, but this deliberate act of environmental destruction will contribute to a feedback loop. These fires release carbon dioxide and kill the trees and species that not only remove greenhouse gasses from the air but are part of vital fragile ecosystems. As more climate-warming gasses fill the air, extreme weather patterns, drought, species loss, and global warming are exacerbated. These effects then accelerate the spread of infectious disease, global poverty, and human health defects. Overall, climate change and environmental degradation negatively affect both humans and the planet, which makes us less resilient and allows for climate change to accelerate even more aggressively. And the cycle continues.

So, for the sake of our (really wonderful) natural planet, and humankind, it is crucial that we try to hinder this feedback loop and make climate action a priority around the world. And, although individually we can try to have a more reciprocal relationship with the planet, our actions and voices carry more weight collectively, which is where Climate Week NYC comes in.

What is Climate Week NYC?

Organized by The Climate Group, Climate Week NYC is an annual week-long gathering for citizens and global leaders to join forces and take action to mitigate environmental harm caused by human activity. There will be a number of public events each day from September 23-29, including tours, film screenings, conferences, and more.

Fun fact: Swedish teenager and activist Greta Thunberg sailed across the Atlantic all the way from England to meet with UN Secretary-General Antonio Guterres, and to attend the United Nations Climate Action Summit, scheduled on the first day of Climate Week NYC!

(more…)

Recent Developments in Off-Shore Wind Energy Production and Renewable Energy Storage

Overview

There have been several local and global developments recently with regards to off-shore wind turbines. Advancements in energy storage from both wind and solar energy, coupled with the increased rate of adoption of wind turbines could serve as a major step towards a more renewable-based energy grid and a more sustainable future.

Image of off shore windmills

Block Island Wind Farm, courtesy of the US Department of Energy

Updates on Energy Production

First, let’s explore some recent news surrounding the adoption of off-shore wind turbines. On a global scale, Scotland’s Hywind project recently proved that technology developed for and by the oil drilling industry can be successfully applied to off-shore wind turbines.[2] The floating 30 MW wind farm, made up of five turbines off the Aberdeenshire coast, has been operational since October 2017. During a three-month period of stormy conditions from November 2018 to January 2019, the wind farm managed to continue energy production at 65% of their maximum capacity. Note that during this period, a North Atlantic hurricane produced swells up to 27 feet! Over the course of a year “maximum capacity” is approximately 135 GWh of electricity – or enough to power 20,000 Scottish homes. To ensure that the turbines can withstand weather events on that scale, the floating turbines are ballasted by 5,000 tons of iron ore, and 1,323 tons of chain anchor it to the seafloor. This off-shore farm proves that wind turbines can be successfully deployed in deeper waters where it would be increasingly expensive to extend the physical structure of the turbine tower to the seafloor. Additionally, the US, UK, Ireland, Portugal, Spain, France, and South Korea all have started to piggyback off the success of the Hywind farm in various ways. For instance, South Korea partnered with the Equinor, the primary backer of Hywind, to conduct a feasibility study for a 200 MW farm that would be located off the coast of Ulsan.[3][4][5][6]

(more…)

What the Climate Mobilization Act Means for Developers, Designers, and Construction Teams

 

Image of central park and New York City buildigns

The construction industry has been increasingly focused on meeting ever-tightening codes and achieving higher ratings in sustainability certification programs (e.g., LEED, Passive House, etc.). These standards do a good job of raising the bar, but there is a new bar in town and we’re not talking about whiskey.

Local Law 97

NYC’s Local Law 97 of 2019 establishes carbon emissions limits for buildings 25,000 square feet and larger. These emissions limits, which are based on current building performance data, will begin in 2024 and will rachet down in 2030 and beyond. While we continue to work with building owners and portfolio managers of existing buildings (“What Does the Climate Mobilization Act Mean for Building Owners?”), we need to make sure that new buildings and major renovations are set up for success. Developers, designers, and construction teams must take LL97 into account during design, construction and turnover to protect the value of these new assets.

A developer or asset manager’s least favorite word is probably uncertainty, and now there’s a whole new host of uncertainties to think about:

(more…)

Electrify Everything? Part 2.

Heat Pump Water Heaters in Multifamily Buildings

In Electrify Everything? Part 1 that I wrote several months ago, I mentioned that integrated tank heat pump water heaters (HPWHs) can work well in single family homes — even in colder climates. For example, we see quite a few installed successfully in basements in the Northeast. These devices remove heat from the surrounding air, so there needs to be enough heat in the basement air for them to work effectively. During the winter, a home’s space heating system probably needs to work harder to make up for the HPWH. In the summer, the HPWH provides a bit of extra cooling and dehumidification. We put together some guidelines a few years ago on how to get the most from these systems in single family homes.

Image of heat pump

Some places where I’ve seen problems:

  •   Installing a HPWH in a basement closet. Even if a closet has louvered doors, there’s not enough heat/air for a HPWH to work well.
  • HPWHs are relatively loud. If there’s a finished part of the basement (e.g., bedroom or office), the noise can be disruptive.
  • Sometimes there is trivial heat gain to the basement (from outdoors, mechanical equipment, etc.). When a HPWH removes heat from the air, such a basement can quickly become too cold for the water heater to work efficiently (and too cold for comfort if someone uses the basement).

But overall, HPWHs in single family basements can work effectively.

(more…)

It’s Time to Focus on Our Schools

If you are a parent like me, I am sure you cherish your kids and seek to offer them the best opportunities in life. I even moved to a different school district. And, while the education is top-notch in my town, I have come to realize that it really doesn’t matter what school district you are in…all our schools need help. I am not talking about smaller class sizes, better pay for teachers, after-school programs, and more school supplies, although those are important. School buildings need attention. With budgetary pressures, a lot of maintenance and repairs are being deferred and schools are not aging well. Whether it is repairing existing systems, replacing systems at the end of their useful life, renovating, or building a brand-new school to service your community for future generations, advocate for your Board of Education (BoE) to think holistically about improving the conditions for our children.

Why My Call to Action?

This year I was asked to join our elementary school’s Tools for Schools committee, which is tasked with implementing an indoor air quality (IAQ) management plan. This experience gave me an opportunity to get involved and provided me insight into the school’s systems and the operations and maintenance (O&M) processes that were in place.

Unfortunately, at the start of the 2018 school year, mold issues were identified in our local middle school and the building was closed. In fairness, I quickly realized that buildings were outside the BoE members’ knowledge base. Afterall, they are educators, not facility managers or building scientists. They sought outside consultants but didn’t know the right questions to ask. After some time, the BoE decided to get input from local experts in the community. Fortunately, we have several experts (including me) who were willing to volunteer their time. As part of a task force, we laid out a strategy to remediate the mold issues in the school and to implement short- and long-term repairs to minimize/eliminate water incursion and elevated moisture issues within the building.

I am not saying you must get involved at this level, but I do encourage you to attend a BoE meeting and start asking questions related to IAQ. Ask if the school has deferred maintenance needs and if/when these are being addressed in the annual budget. Ask when (if) comprehensive physical needs assessments and energy audits were performed on all school buildings. Educate yourselves; then help educate your BoE and your community on IAQ guidelines for schools. Here are some great resources:

How Can SWA Help?

In working with schools, I have learned that one of the greatest challenges school decision-makers face is not knowing where to turn for support and guidance. Steven Winter Associates, Inc. (SWA) has been working to improve educational facilities for decades. Whether you have questions related to mold, moisture, comfort, absenteeism, accessibility, high utility bills…on up to zero energy design and progressive learning environments, SWA can support you. Here is just a sample of past school projects that SWA has worked on:

(more…)

Five Steps to Get Started with Net Zero Energy Buildings

Net zero buildings are becoming increasingly mainstream, with many jurisdictions adopting policies to move towards net zero new construction codes. A good overview of advanced energy codes is available on the Getting to Zero Forum, which includes a snapshot of activity around the country including Washington, DC, New York and Massachusetts.

What Does it Mean to be Net Zero?

The term “net zero” commonly refers to zero-energy buildings. In simple terms, a zero-energy building is one that produces as much energy as it consumes on an annual basis. There can be nuances and caveats to this definition, but for now, we want to bring you up to speed on five key net zero energy strategies to consider if you’re interested in developing a net zero building.

1. Maximize space for on-site renewable energy.

How tall is your building?

  • Any building over five stories will be challenging, if not impossible, to achieve net zero with on-site renewable energy production alone because building energy demand will likely exceed available site area. Maximize your solar with a smart layout and consider if other renewables, such as geothermal, are possible.
Image of roof layout

Typical roof layout for multifamily building, including necessary setbacks for fire access, mechanical equipment access, and shading from bulkheads. Fire access is based on FDNY guidelines.

Do you have other spaces available for solar photovoltaics (PV)?

  • Your development may have a separate parking garage or parking lot on site. These are great places to install a PV system, which can significantly increase the amount of on-site renewable energy production and help make achieving net zero more of a reality.

Do I have to have all renewables on-site to be net zero?

  • If you don’t have enough room for on-site renewables, you can look into purchasing off-site renewable energy options, such as community solar, power purchase agreements, or renewable energy credits.

Now that you’ve considered renewables, let’s move on to net zero building design considerations.

(more…)

20 Years of Wintergreen!

A lot has happened since the start of the WinterGreen newsletter, which was first distributed 20 years ago via fax machine. From the inception of LEED, to the Climate Mobilization Act, WinterGreen has covered it all.

In honor of its anniversary, we are looking back at the milestones that occurred along the way and making predictions for the future…WinterGreen Banner circa 1999

1999 – Steven Winter Becomes Chairman of the US Green Building Council

Image of Steven Winter as USGBC ChairmanAs Chairman of the U.S. Green Building Council from 1999 to 2003, Steven Winter helped guide the organization through a period of immense growth. This included the launch of Leadership in Energy and Environmental Design, also known as the LEED® Rating System, and Greenbuild, the nation’s largest green building conference and expo.

 

2000 – SWA Receives NYSERDA Pioneer Award

Image of Steven Winter with NYSERDA AwardAt a gala event celebrating the 25th anniversary of the New York State Energy Research and Development Authority (NYSERDA), Steven Winter Associates (SWA) was presented with the NYSERDA Pioneer Award for their extensive contributions to making buildings more energy efficient and sustainable.

 

2001 – Green Building Guidelines Book Published for Home Builders

Image of Green Building Guidelines bookIn conjunction with the U.S. Department of Energy (DOE), the National Renewable Energy Lab (NREL), and the Sustainable Buildings Industry Council (SBIC), SWA staff collaborated to create “Green Building Guidelines: Meeting the Demand for Low-Energy, Resource-Efficient Homes.” The book provided green building techniques and strategies for home builders and residential construction professionals.

 

2002 – SWA Helps DEC Become New York State’s First Ever LEED Certified Building

Image of New York DEC Headquarters in AlbanyWorking with NYSERDA, Picotte Companies and WCGS Architects, SWA provided certification support to the design team, earning the project LEED V2.0 Silver. SWA’s services included initial LEED tabulations and goal setting, detailed LEED V2.0 evaluation reporting, and completion of the final documentation package, which led to the certification of New York State’s first ever LEED building.

 

2003 – The Solaire Declared Nation’s First “Green” Residential High-rise

Image of The SolaireNew York Governor George Pataki dedicated The Solaire as the country’s first “green” residential high-rise building, calling it “a benchmark for urban sustainable development and for green buildings worldwide.” SWA supported the design team on this project from conceptual design phase through construction administration. The Solaire, located in New York’s Battery Park City, was the first residential building to be completed in downtown Manhattan after the terrorist attacks of September 2001, and was the first beneficiary of Governor Pataki’s green building tax credit.

 

2004 – SWA Joins Project Team for Oculus Terminal at World Trade Center

Image of World Trade Center PATH TerminalLed by the joint venture of DMJM+Harris and STV, as well as the internationally renowned architect, Santiago Calatrava, SWA was invited to join the project team to provide energy efficiency and sustainable design consulting services for the new World Trade Center station, also known as the the Oculus. The rebuilt PATH terminal is incorporated into the design.

 

2005 – USGBC Announces LEED for Homes Pilot Program

Image of home under constructionExcited to announce the first ever LEED program for residential construction, the USGBC immediately began seeking applicants to test the effectiveness of the all new LEED for Homes through a Pilot Program. LEED for Homes, which is considered a green building milestone, was made possible by a passionate committee of industry professionals co-chaired by Steven Winter.

(more…)

Rapidly Changing Brooklyn Neighborhood Welcomes Affordable and Sustainable Housing Development

image of Livonia Apartments

Courtesy of MAP Architects

The Livonia Apartments is Phase II of an affordable sustainable housing development in the rapidly changing neighborhood of East New York, Brooklyn. Through a partnership with the NYC Department of Housing Preservation and Development (HPD) and the New York City Housing Development Corporation (HDC) and designed by Magnusson Architecture and Planning (MAP), BRP Companies and partners developed this mixed-use, four-building complex to provide 292 apartments of both affordable and supportive housing, including 10% of units specified for persons with disabilities and municipal employees. In addition, Livonia II provides 30,000 square feet of community and retail space for the neighborhood.

The size and density of The Livonia Apartments project represented an opportunity to set a higher benchmark in green design strategies. Mayor Bill di Blasio stated at the groundbreaking, “For decades these vacant lots have been a blight on this neighborhood. Today, we’re breaking ground on a project that will deliver the affordable housing, good local jobs and vital services this community needs. We believe in a city where every neighborhood rises together, and where we make investments that give more people a shot at a better life.” Although the development straddles the busy elevated L & 3 trains and the Livonia Ave. station, the buildings’ facades are angled to minimize the sound and rattle from the trains, while maximizing privacy and natural light.

(more…)

The Impact of Energy Star’s Portfolio Manager August 2018 Updates on NYC’s Local Law 33 Grades

Image of Letter Grades from SmartBuildings.NYC site

Letter grades are coming!

NYC’s building owners and real estate management firms now have one more thing on their plate to consider: Local Law 33 of 2018. LL33 compliance will assign letter grades to buildings required to benchmark energy and water consumption. The energy efficiency score will relate to the Energy Star Rating earned using the U.S. EPA Energy Star Portfolio Manager (PM). The law will come into effect on January 1, 2020, and will utilize the previous year energy data to set the energy efficiency score and letter grade as follows:Picture of Buildings, with quote "Your energy letter grade will be posted in your lobby in 2020. Are you ready?"

A – score is equal to or greater than 85;
B – score is equal to or greater than 70 but less than 85;
C – score is equal to or greater than 55 but less than 70;
D – score is less than 55;
F – for buildings that fail to submit required benchmarking information;
N – for buildings exempted from benchmarking or not covered by the Energy Star program.

Why is my letter grade lower than expected?

Property owners should be made aware that if their property earned an energy efficiency score of 75 for the 2018 Benchmarking filing, the new score for the 2019 benchmarking filing may have fallen as much as 20 points. In LL33 terms, what could have been a letter grade “B” could now be “C” or “D” based on PM updates implemented in August 2018. Property owners will want to learn how the Energy Star PM update will affect their LL33 letter grade.

To understand the correlation and impact that the August 26, 2018 Energy Star PM update will have, it is important to look back at what took place as part of that update. (more…)

The owner of this website has made a commitment to accessibility and inclusion, please report any problems that you encounter using the contact form on this website. This site uses the WP ADA Compliance Check plugin to enhance accessibility.